Specification


VCI-165P 120LE/230LE

Exterior dimensions

(Projections not included) 

620 mm x 740 mm x 850 mm/ 24.4 in. x 29.1 in. x 33.5 in. (W x D x H)

Interior dimensions

W481 mm × D531 mm × H640 mm

Capacity

Approx. 163 L

Outer facing

Electrogalvanized steel sheet (Baked powder coating)

Inner facing

Stainless steel plate (SUS304, SUS430)

Shelf board

W455 mm × D468 mm × H23 mm 4 boards in the standard configuration (10 boards max.)

Access board

φ29 mm (Standard configuration)

Temperature control method

Digital PID control

Temperature control range

Room temperature plus 5°C to 50°C (0.1°C steps)

Temperature control accuracy

±0.1°C

Temperature uniformity

±0.3°C

Temperature control range for dry-heat sterilization

50°C to 160°C (1°C steps)

Temperature uniformity regarding dry-heat sterilization

±3°C

Sterilization temperature setting time

0.1 to 10.0 hours

CO2 sensor

NDIR sensor

CO2 concentration control range

0.0%~20.0%

CO2 concentration control accuracy

±0.1%

O2 sensor

-

O2 concentration control range

-

O2 concentration control accuracy

-

Humidifying method, humidity

Natural evaporation method (Vat water filling), 95% ±4% RH

Safety devices

Over-temperature protection, over-temperature alarm, CO2 alarm, O2 alarm, other various alarms

Product weight

90 kg

Power supply

Single-phase 110-120V AC, 50/60 Hz, or Single-phase 220-240V AC 50/60 Hz, 7.5 A

Power consumption

750 W(max.)

Power consumption (Watt-hour)

75 Wh (at room temperature 25°C, set temperature 37.0°C, stable operation)

Working temperature range

10°C ~ 30°C

Working humidity range

30% ~ 80%RH

Storage temperature range

-20°C ~ 50°C

Storage humidity range

20% ~ 80%RH

Options

Cell monitor

Analogue output

Alarm contact output

Gas guard

Door lock

Cart

Vertical joint bracket

Dust collection filter

VMI-165P 120LE/230LE

Exterior dimensions

(Projections not included) 

620 mm x 740 mm x 850 mm/ 24.4 in. x 29.1 in. x 33.5 in. (W x D x H)

Interior dimensions

W481 mm × D531 mm × H640 mm

Capacity

Approx. 163 L

Outer facing

Electrogalvanized steel sheet (Baked powder coating)

Inner facing

Stainless steel plate (SUS304, SUS430)

Shelf board

W455 mm × D468 mm × H23 mm 4 boards in the standard configuration (10 boards max.)

Access board

φ29 mm (Standard configuration)

Temperature control method

Digital PID control

Temperature control range

Room temperature plus 5°C to 50°C (0.1°C steps)

Temperature control accuracy

±0.1°C

Temperature uniformity

±0.3°C

Temperature control range for dry-heat sterilization

50°C to 160°C (1°C steps)

Temperature uniformity regarding dry-heat sterilization

±3°C

Sterilization temperature setting time

0.1 to 10.0 hours

CO2 sensor

NDIR sensor

CO2 concentration control range

0.0%~20.0%

CO2 concentration control accuracy

±0.1%

O2 sensor

Galvanic battery-type sensor

O2 concentration control range

2.0%~80.0%

O2 concentration control accuracy

±0.5%

Humidifying method, humidity

Natural evaporation method (Vat water filling), 95% ±4% RH

Safety devices

Over-temperature protection, over-temperature alarm, CO2 alarm, O2 alarm, other various alarms

Product weight

90 kg

Power supply

Single-phase 110-120V AC, 50/60 Hz, or Single-phase 220-240V AC 50/60 Hz, 7.5 A

Power consumption

750 W(max.)

Power consumption (Watt-hour)

75 Wh (at room temperature 25°C, set temperature 37.0°C, stable operation)

Working temperature range

10°C ~ 30°C

Working humidity range

30% ~ 80%RH

Storage temperature range

-20°C ~ 50°C

Storage humidity range

20% ~ 80%RH

Options

Cell monitor

Analogue output

Alarm contact output

Gas guard

Door lock

Cart

Vertical joint bracket

Dust collection filter